Ceramifiable silicone rubber for fire-resistant cables: compound formulation, ceramification mechanism, and circuit-integrity standards
A fire-survival alarm cable was bent too tightly around a trunking bend during installation. Six months later it failed its BS 6387 CWZ test — the mica tape had delaminated at the bend, the conductor sagged into the char, and the circuit opened inside 30 minutes. The specifier needed an insulation that survives installation abuse and still holds a circuit alive at 950 °C for 3 hours. This article explains how a ceramifiable silicone rubber compound is formulated, why it sinters into a porcelain-like ash instead of burning away, and what a cable engineer or procurement manager must demand on the datasheet before switching from mica tape to a one-step extruded insulation.
Why fire-survival cables need a ceramifying insulation
Fire-resistant (“fire-survival”) cables must keep their circuit working during and after a fire, so that fire alarms, emergency lighting, smoke extraction fans, sprinkler controls, evacuation lifts and public-address systems stay live while people get out. The relevant tests are circuit-integrity tests on the finished cable, not burn tests on the polymer. Plain PE or PVC insulation disappears in minutes and the conductors short or part — so a ceramic-forming layer is engineered around the conductor to bridge the gap.
| Fire test | Cable scope | Flame / protocol | Duration | What must keep working |
|---|---|---|---|---|
| IEC 60331-21 | Cables ≤ 20 mm OD, power & control | ~750–830 °C flame, rated voltage on conductors | 30–120 min (commonly 90 min) | Continuity of every core, no short to earth |
| BS 6387 Category C | Power, control, alarm | 950 °C fire alone | 3 h | Circuit integrity at rated voltage |
| BS 6387 Category W | Same as above | 650 °C fire + water spray | 15 min fire + 15 min spray cycles | Circuit integrity through hose-stream shock |
| BS 6387 Category Z | Same as above | 950 °C fire + mechanical shock | 3 h + periodic impact | Circuit integrity through vibration/impact |
| BS EN 50200 / EN 50267 | Small-diameter data & alarm cables | PH30 / PH60 / PH120 furnace protocol | 30 / 60 / 120 min | Loop integrity for addressable systems |
“PH120” means the cable survives at least 120 minutes in the standard furnace protocol — the benchmark most safety specifiers write into fire-alarm loop specifications.
How ceramifiable silicone compounds work: filler systems and the ceramification temperature ladder
A typical silicone rubber compound for fire-resistant cable insulation is a platinum- or peroxide-cured VMQ (vinyl-methyl silicone) base loaded with 30–55 phr of a ceramifying filler system: calcined kaolin (an aluminosilicate that forms glassy phases), low-melting borosilicate glass frit (the liquid-phase flux), mica flakes (crack-bridging reinforcement for the ceramic shell), and optional quartz, wollastonite, or zinc borate as a flame-retardant synergist. Platinum cure gives lower compression set and cleaner thin-wall extrusion; peroxide cure is cheaper for thicker jacketing.
The “magic” is the staged temperature response of the filler system, summarised below.
| Temperature range | Process happening inside the compound |
|---|---|
| < 350 °C | Normal high-temperature silicone rubber behaviour (service up to ~180–200 °C, cold bend to -60 °C) |
| 350–500 °C | Polymer crosslinks and begins pyrolysing to amorphous silica; organic backbone is consumed |
| 500–650 °C | Borosilicate glass frit softens, flows and wets the silica/kaolin particles — liquid-phase sintering begins |
| 650–1000 °C | Viscous sintering completes; a self-supporting, porcelain-like ash forms with compressive strength of 1–5 MPa |
| Without the frit | Ash crumbles to powder, the conductor sags, the circuit fails — filler-system design is the core IP |
That 1–5 MPa ash strength at 900–1000 °C is what physically holds the conductors apart even if the copper softens and tries to sag through the burning zone — and it is what allows the cable to keep passing current for 30–120+ minutes under rated voltage.
Ceramifiable silicone vs mica tape: production and performance comparison
Mica/glass tape is the classical answer, with decades of installed base and very low smoke. But the tape is wrapped on a separate lapping line, bonded with a binder resin that limits the upper service temperature, and it can delaminate on tight installation bends — exactly the failure mode that opened this article. A ceramifiable silicone insulation extrudes on a standard silicone crosshead line, bonds directly to the conductor, and tolerates the bending and flexing that happens before the fire.
| Attribute | Mica/glass tape insulation | Ceramifiable silicone insulation |
|---|---|---|
| Insulation process | Multi-step: extrusion of inner layer + mica/glass tape lapping + binder + outer jacket | One-step extrusion directly onto the conductor |
| Typical wall thickness | Thicker, dictated by tape overlap | 0.5–1.0 mm thin-wall possible |
| Bending / flexing tolerance | Risk of tape delamination at tight bends | Bonds to conductor; tolerates repeated flexing before fire |
| Continuous service temperature | Capped by binder resin (often 90–105 °C) | -60 °C to +180–200 °C (VMQ) |
| Fire behaviour | Mica is inherently non-combustible; relies on tape integrity | Forms self-supporting ceramic ash at 650–1000 °C, 1–5 MPa |
| Compound cost per kg | Lower | Higher (specialty filler package) |
| Capex / process change | Need lapping machines, overlap QC, scrap control | Standard silicone silicone extrusion crosshead line |
Cable constructions already running on ceramifiable silicone insulation include thin-wall 0.5–1.0 mm alarm and control cores (replacing taped mica), 1.5–6 mm² fire-survival power feeders, flexible cords for emergency lighting and exit signs, PH120 alarm-loop data cables, and EV charging / battery-room cables where flame, heat and smoke all matter. Typical property targets are oxygen index ≥ 28–35%, elongation at break 150–400%, tensile 5–9 MPa, cold bend -40 °C, and post-fire conductor separation held by the ash.
Compound qualification checklist and standards stack for buyers
Fire-survival cables are safety-critical and specified by standard, not by price. Switching from mica tape to a ceramifiable silicone rubber insulation changes the entire production-line economics, so compound qualification, in-house circuit-integrity testing and documentation are what separate a reliable supplier from a commodity vendor. Use the numbered checklist below when qualifying a new compound.
- Demand circuit-integrity test reports on the finished cable at the actual diameter and wall — IEC 60331-21 for ≤ 20 mm OD, BS 6387 CWZ where specified.
- Ask for ash compressive-strength data at 750 °C and 950 °C (typical target 1–5 MPa at 900–1000 °C).
- Get the filler-system composition disclosed: glass-frit content, softening point, mica grade, kaolin source.
- Confirm cure system (platinum vs peroxide) and scorch safety at your actual extrusion temperatures.
- Verify smoke and halogen results on the final construction — IEC 61034-2 (light transmittance ≥ 60%) and IEC 60754-1 (HCl yield ≤ 0.5% for “zero halogen”).
- Confirm continuous-service rating and aging — e.g. 180 °C × 168 h with tensile/elongation retention reported.
- Check colorability and printing adhesion for core identification and outer-sheath marking.
- Cross-check the full cable against the standards stack below before release.
| Test | Standard | Typical requirement |
|---|---|---|
| Single / bunched flame retardance | IEC 60332-1 / IEC 60332-3 | Self-extinguishing, limited flame spread |
| Smoke density | IEC 61034-2 | Light transmittance ≥ 60% in 3 m cube |
| Halogen acid gas | IEC 60754-1 | HCl yield ≤ 0.5% (“zero halogen” claim) |
| Flaming droplets / heat release | EN 50399 | Euroclasses B2ca–Cca for CPR building cables |
| Circuit integrity | IEC 60331-21 / BS 6387 CWZ / EN 50200 | 30–120 min continuity at rated voltage |
A ceramifiable silicone insulation plus an LSZH outer sheath can meet all of these in one construction, including the CPR Euroclass B2ca–Cca band that public-building specifiers now write into tender documents. For related coating applications outside the cable — for example an EV battery pack fire barrier built on similar ceramifying chemistry — see our article on ceramifiable fire-barrier coating technology.
Frequently Asked Questions
What is ceramifiable silicone rubber and how does it protect fire-resistant cables?
Ceramifiable silicone rubber is a VMQ silicone compound loaded with 30–55 phr of a glass-frit, kaolin and mica filler system. At 500–650 °C the borosilicate frit softens and wets the silica/clay particles, and by 650–1000 °C the residue sinters into a self-supporting ceramic ash with 1–5 MPa compressive strength — strong enough to hold the conductors apart and keep the circuit live for 30–120+ minutes under IEC 60331-21 or BS 6387 CWZ.
Ceramifiable silicone insulation vs mica tape — which is better for fire-survival cables?
Mica tape has decades of field track record and very low smoke, but lapping adds process cost and the tape can delaminate on tight installation bends. Ceramifiable silicone extrudes in one step directly onto the conductor, bonds to it, tolerates repeated flexing before the fire, and allows walls as thin as 0.5–1.0 mm; the trade-off is a higher compound cost per kg and the need to validate ash strength at the exact wall thickness you run.
Which standards must a ceramifiable silicone cable meet for fire-alarm and emergency circuits?
For circuit integrity the cable must pass IEC 60331-21 (≤ 20 mm OD, 750–830 °C flame, 30–120 min), BS 6387 Category C (950 °C for 3 h) and, where specified, W (fire + water) and Z (fire + mechanical shock); small-diameter data cables typically need EN 50200 PH30/PH60/PH120. The construction also has to clear IEC 60332-1/-3 for flame spread, IEC 61034-2 (≥ 60% transmittance) for smoke, IEC 60754-1 (≤ 0.5% HCl) for halogen acid, and EN 50399 Euroclass B2ca–Cca for CPR compliance.
Next step: talk to a fire-cable compound specialist
Choosing between mica tape and ceramifiable silicone insulation is a safety decision that locks you into a production process for years. Send us your cable design (diameter, wall thickness, voltage rating, target fire test) and we will line up a technical team review, sample compound from the matching filler-system family, and a joint test plan covering IEC 60331-21 / BS 6387 CWZ, IEC 61034 and IEC 60754 on your finished construction.
Related Reading
- Ceramifiable Silicone Rubber: What It Is and Why It Matters for Fire Safety
- Ceramifiable Silicone Coating as an EV Battery Fire Barrier: Composition vs Mica, Aerogel and Intumescent
- Silicone Rubber Extrusion: Tubing, Profiles and Cord Manufacturing Guide
- Closed-Cell Silicone Foam: Properties and Applications in Sealing, Insulation and Fire Protection
- Silicone Rubber Compounds for Industrial Applications